Instrumentarium OP200 D

A proven leader in panoramic imaging

 

A new era of usability

 

Operators of the unit and their knowledge of the imaging methods may change with time – quality of Orthopantomograph and Orthoceph images will not.

 

 

Accurate and stable patient positioning

 

Correct patient positioning is assured by three positioning laser lights. Frankfurt and midsagittal lights aid in finding the correct angulation of the patient's head and the occlusion correction light ensures proper anterior positioning.
A rigid 5-point positioning system including forehead support, chin rest and bite fork eliminates patient movement. The open design allows easy viewing and positioning of the patient from either the left or right side.

 

_

 

 

Correct imaging values – automatically

 

The OP200 D has a method for dose-controlled Automatic Exposure Control. The system measures patient bone thickness from the ramus and defines individual exposure values for patients with different sizes. This also enables individual Automatic Spine Compensation values to reduce spinal shadow in the image for each patient.

 

Dental 2D Panoramic / OPG X-Ray Instrumentarium OP200 D

 

 

V-shaped beam – clinically proven imaging geometry

 

The V-shaped X-ray beam adapts to the human anatomy, providing even greater detail and a wider mandibular image layer. The V-shaped X-ray beam also allows for more penetrating power for the thicker maxilla area.

A V-shaped beam supports better imaging of the human anatomy than a standard beam and ensures a homogeneous image.

_

 

Special geometry

 

 The Ortho Zone programme provides a special geometry to solve two common imaging problems: metal artefacts in the molar region of the condyle and the need for an exceptionally wide anterior layer for patients with malocclusion.

_

 

 Partial programmes – decrease of dose

 

When a full panoramic image is not required, 1 to 5 segments of the horizontal image can be selected to expose only regions of diagnostic interest.

Dental 2D Panoramic / OPG X-Ray Instrumentarium OP200 D

 

 

Cephalometric 

 

ORTHOCEPH OC200 D

Fully adjustable scanning

The OC200 D incorporates an advanced user-adjustable lateral scan method to expose only the desired portion of the skull. This method reduces the scanning time to a minimum of five seconds and reduces patient dose considerably.

The OC200 D uses a patented Automatic Facial Contour (AFC) method for soft tissue enhancement in lateral views. The unit automatically adjusts the exposure values during scanning for better soft tissue definition.

_

  Dental 2D Panoramic / OPG X-Ray Instrumentarium OP200 D

 

Clinically correct image geometry

 

In order to produce equal and accurate horizontal and vertical magnification, the OC200 D uses a patented method of synchronised tube head horizontal sweep and sensor movements while keeping the focal spot in the same position.

 

Stable patient positioning

 

The Frankfurt horizontal plane laser light, nasion support and rigid ear rods with locking system make patient positioning easy and convenient.

 

Perfect fit for your clinic

 

OC200 D can be set up in your clinic for right- or left-handed cephalometric imaging and is “field changeable”. SMARTPAD can be installed on either side of the unit or on the wall.

 

Full range of projections

 

The Orthopantomograph patient positioning system provides a variety of imaging projections for cephalometric radiography. It is a comprehensive diagnostic device that includes lateral, facial, posterioranterior and oblique projections, as well as the possibility of hand and wrist imaging.

 

 

VT – Volumetric Tomography

 

 

The optimal solution

 

The ORTHOPANTOMOGRAPH OP200 with VT is the most advanced and comprehensive cross-sectional imaging system on the market. It provides accurate and valuable information especially for implant planning. With the VT there is no need for unit modifications or purchasing expensive sensors.

VT provides a continuously viewable stack of 256 cross-sectional slices. Each slice has a minimum thickness of 0.23 mm. Selection of the region of interest could not get easier.

_

 

Implant planning tools

 

The implant planning tool helps you to easily determine the correct implant for treatment. The tool contains implant models from leading manufactures. The software also provides the necessary measuring tools.

Dental 2D Panoramic / OPG X-Ray Instrumentarium OP200 D

Dental 2D Panoramic / OPG X-Ray Instrumentarium OP200 D

 

Easy navigation of slices

 

The VT system has a slice navigator that shows the exact position of the cross-sectional slice in real time.

_

 

Excellent image quality

 

Our unique reconstruction method produces high-quality images using a patented method for making cross-sectional slices with narrow X-ray beam and standard panoramic sensor. This has been proven to give better image quality than other known reconstruction methods.

 

 

 

 

A new era of usability

 

Operators of the unit and their knowledge of the imaging methods may change with time – quality of Orthopantomograph and Orthoceph images will not.

 

SMARTNAV - Interactive navigator

 

The SMARTNAV navigation software provides easy selection of imaging programs, arch sections, lateral scanning start position, and more.

Dental 2D Panoramic / OPG X-Ray Instrumentarium OP200 D

Dental 2D Panoramic / OPG X-Ray Instrumentarium OP200 D

 

SMARTPAD full-colour touch screen


The large 12.1" SMARTPAD touchscreen has an easy- to-use menu with simple and intuitive navigation. SMARTPAD option is available for all OP200 D units.                                                                                                   

Patient positioning animations

 

If in doubt, patient positioning animations specific to each imaging programmes demonstrate the proper patient positioning procedure.

 

Instant dynamic help

 

This feature provides quick and convenient information related to the imaging programmes, such as the purpose of the programme selected.

Technical specifications

generator  high frequency DC, 75–150 kHz
X-ray tube D-051S
focal spot size 0,5 mm, according to IEC 336
total filtration min 2.5 mm Al
 tube voltage  57 – 85 kV
tube current  2 – 16 mA
nominal voltage 110/230 VAC +/- 10% 50/60 Hz
main fuses 10 A @ 230 VAC, 15 A @ 110 VAC
power consumption  2.3 kVA @ 230 VAC, 1.65 kVA @ 110 VAC

 