Overview of laboratory drives from KaVo

Overview of all KaVo laboratory drives, control units, and their compatibility

Overview of our laboratory drives

Laborantriebe_Treppe_en_neu

Overview of laboratory drives

 

K-ERGOgrip

K-POWERgrip

K5plus

Speed 1,000 - 50,000 rpm in clockwise operation
No limit in anti-clockwise operation
1,000 - 50,000 rpm in clockwise operation
Anti-clockwise operation limited to 5,000 rpm
1,000 - 35,000 rpm in clockwise operation
Anti-clockwise operation limited to 5,000 rpm
Torque 7 Ncm max. 7.0 Ncm max. 4.5 Ncm
Power 160 Watt max. 150 Watt max. 85 Watt
Chucking system Retention force min. 100 N
changing the chuck without tools
Retention force min. 70 N
changing the chuck with tools
Retention force min. 70 N
changing the chuck with tools
Temperature increase on load Extra low + 5°K Very low + 9°K Low + 13°K
Dimensions L = 140 mm short
D = 28 - 38 mm oval for peeling grip
D = 11mm pen grip
L = 165 mm
D = 25 - 29 mm oval for peeling grip
D = 14 mm pen grip
L = 149 mm
D = 25 - 28 mm peeling handle
D = 16 mm pen grip
Weight Handpiece 202 g Cable 107 g Handpiece 250 g Cable 105 g Handpiece 216 g Cable 103 g
Ease and convenience 2K Softgrip shank
Two different, exchangeable ergonomic handles
optimum hand-arm angle
Low-vibration
2K Softgrip shank
Flexible and lightweight handpiece cable
lightweight and flexible handpiece cable
Easy to service Small number of components
One-shaft system (only 2 screws to change both ball bearings)
Anti-soiling cap
Patented sealing system
Small number of components
One-shaft system (only 9 component parts)
anti-soiling cap
Control Can be connected to K-Control TLC control units with knee, foot and table versions
(and the earlier K-Control knee, foot and table version)
Can be connected to K-Control TLC control units with knee, foot and table versions
(and the earlier K-Control knee, foot and table version)
Can be connected to K-Control TLC control units with knee, foot and table versions
(and the earlier K-Control knee, foot and table version)
Actuation of accessory devices with K-Control TLC via 12-V relay with K-Control TLC via 12-V relay with K-Control TLC via 12-V relay
 

 

Overview of control units

 

K-Control TLC

K-Control

Model Knee, foot, and table versions Knee, foot, and table versions
Plane 4-colour display; easy recognition of selected programme (speed / torque) 2-digit digital display
Programmes 4 programmes can be set (speed / torque); selectable and programmable through speed press-button none
Speed Pre-selectable, to 30,000 rpm with safety limit / switch; option of switching to counterclockwise operation, limited to 5,000 rpm with some handpieces; K-ERGOgrip up to 50,000 rpm in counterclockwise operation as well Pre-selectable, to 30,000 rpm with safety limit / switch; option of switching to counterclockwise operation, limited to 5,000 rpm (incl. K-ERGOgrip)
Torque Limit can be set; for gentle processing of materials  
Control of accessory devices such as suction Special control line socket for suction, e.g. EXTRAmatic or SMARTair; relay output 12V for additional accessory devices Special control line socket for suction available
Assembly On KaVo standard suspension rail for knee version On KaVo standard suspension rail for knee version
Handpieces K-ERGOgrip
K-POWERgrip, K12, K11
K-5plus, K5
K9 (4930 / 960 / 970)
(K-ERGOgrip from 12/2007)
K-POWERgrip, K12, K11, K10 with adaptor
K-5plus, K5
K9 (4930 / 960 / 970)
SF with cable


Overview of control units_

Compatibility of laboratory drives and control units

  K-Control TLC
(4955, 4956,
4957)
K-Control
(4960, 4965,
4970)
K4 control units
(4974, 4964,
4954)
K-ERGOgrip
4944
x x  
K-POWERgrip
4941
x x  
K5plus
4911
x x  
K4plus
4912
    x
K9
4930/
970/960
x x  
SF
4005
  x  
K12
4940
x x  
K11
4990
x x  
K5
4910
x x  
K4
4914
    x

 

_

Overview of laboratory drives

 

K4plus

K9

SF

Speed 1,000 - 30,000 rpm in clockwise operation
Anti-clockwise operation limited to 5,000 rpm
1,000 - 25,000 rpm in clockwise operation
Anti-clockwise operation limited to 5,000 rpm
5,000 - 60,000 rpm in clockwise operation
50,000 rpm with K-Control and K-Control TLC
Anti-clockwise operation limited to 5,000 rpm
Torque 4 Ncm 3.3 Ncm 5.7 Ncm
Power max. 85 Watt 42 Watt max. 125 Watt
Chucking system Retention force min. 70 N
changing the chuck with tools
Retention force min. 70 N
changing the chuck with tools
Retention force depends on tightening of the screw-type chuck
Temperature increase on load Low Low Low
Dimensions L = 149 mm
D = 25 - 28 mm peeling handle
D = 16 mm pen grip
L = 149 mm
D = 27 - 32 mm peeling handle
D = 16 mm pen grip
L = 175 mm
D = up to 33.5 mm peeling handle
D = 16 mm pen grip
Weight Handpiece 216 g Cable 103 g Handpiece 230 g Cable 190 g Handpiece 350 g Cable 190 g
Ease and convenience lightweight and flexible handpiece cable    
Easy to service Small number of components One-shaft system (just 9 single components) anti-soiling cap Anti-soiling cap  
Control Can be connected to control unit K4 only
(no longer available)
Can be connected to K-Control TLC control units with knee, foot and table versions (and earlier K-Control knee, foot, table) Can be connected to control unit K-Control (no longer available)
Actuation of accessory devices      

 

Downloads
Brochures
Statements
Brochures Back
Download (1.01 MB)
Statements Back
Download (1.1 MB)
Interested? Get in touch now: