Regular preventive maintenance

Regular preventive maintenance is the prerequisite for safety and provides clear advantages for operational reliability in your practice routine

You can rely on it. Secure your investment’s value in the long term with KaVo’s service kit. Regular maintenance ensures operational reliability of your dental unit.

Product info

  • Kit including all parts needed to perform preventive maintenance check
  • Only KaVo Original Spare Parts used

Benefits

  • Regular maintenance protects and maintains your investment
  • Maintenance carried out in accordance with KaVo quality standards
  • Remain up to date and compliant with hygiene and maintenance standards
  • Reduces downtime and unplanned repair costs

 

_

You can rely on it

Secure your investment’s value in the long term with KaVo’s service kit. Regular maintenance ensures operational reliability of your dental unit. Breakdowns due to wear are reduced to a minimum. In addition, the KaVo maintenance log serves as evidence for the surgery’s quality management system or the surgery’s certification requirements.

Benefits

  • Maximum reliability through regular planned maintenance
  • Planned maintenance periods for smooth surgery routine
  • Maximum transparency of costs through fixed charges for the maintenance contract
_

Exclusive use of Original KaVo Spare Parts

etb_wartungskit_1058_1078_1.png Performance+ Protect

_

You can expect the following maintenance scope

e80-serviceseite-wartungsin.jpg Performance+ Protect

wartungsinhalte-1bild.jpg Performance+ Protect

1. Selective plunger

  • Check function, clean, and replace O rings
  • Disassemble and clean selective housing, replace strainers
  • Disassemble selective plunger, replace springs (E70/E80) and seals

wartungsinhalte-3bild.jpg Performance+ Protect

3. Suction flow valve / external suction

  • Replace O ring and piston packing

 

wartungsinhalte-5bild.jpg Performance+ Protect

5. Patient unit

  • Tumbler spout: check operation and seal
  • Replace jet control and O ring
  • Bowl flush: check operation and seal
  • Replace spittoon bowl strainer

wartungsprotokoll.jpg Performance+ Protect

 Sequence

All maintenance steps follow KaVo's maintenance schedule and are documented step by step. You will receive a maintenance log as evidence.

wartungsinhalte-2bild.jpg Performance+ Protect

2. Aquamat

  • Check overall function
  • Replace reservoir and clean top

wartungsinhalte-4bild.jpg Performance+ Protect

4. Water unit
Check overall function / check for leakage

  • Replace water filter, membrane, and seals
  • Replace non-return valve
  • Replace plug-in filter, water inlet unit fitting and O rings
  • Check system water pressure and adjust if required

 

wartungsinhalte-6bild.jpg Performance+ Protect

 

6. Dentist element

  • Replace return air filter
  • Disassemble and clean control valve
  • Replace plunger, O-ring, and membrane

 

_

Planned maintenance intervals

All maintenance is performed according to KaVo’s maintenance schedule:

1. Checks

  • As part of planned maintenance, all functions of the unit are checked.
  • You will be provided with detailed information on all necessary maintenance tasks that are not included in the maintenance contract.

2. Replacements

  • Regular exchange of wear parts in strict accordance with KaVo’s maintenance schedule.
  • Settings of your treatment unit are modified or adjusted where required.

3. Certification

All legally required checks can be performed as part of annual planned maintenance:

  • Safety checks in accordance with DIN EN 62353
  • Checks of the integrated amalgam separator (in accordance with local regulations)

The service technician issues a maintenance log as evidence.

_

Benefit from our experience

  • The scope of each one of KaVo's maintenance kits is based on many years of practical experience
  • All maintenance kits are tailored to its respective treatment unit
  • Wear parts are replaced in time and settings are corrected where required
  • Have our certified specialist dealers do your maintenance
_

Requirements: Safety through maintenance

All legally required checks can be performed as part of annual planned maintenance:

  • Safety checks
  • Visual inspection
  • Functional checks
  • Electrical checks
  • Check of amalgam separator (according to local regulations)

Maintenance and legally required checks are documented and serve as evidence in the surgery's certification or inspection by authorities.

Interested in maintenance service?

Request and make profit. Ordering is easy and takes only a few clicks. Your information will be passed from KaVo to your dental dealer and he will contact you immediately. KaVo recommend exclusiv cooperation with authorized dealers. Profit from regularly, professional and reliable maintenance service.