KaVo OP 3D Pro

Cone Beam 3D Imaging

The Most Comprehensive 3-in-1 for the Entire Maxillofacial Region

The ORTHOPANTOMOGRAPH™ OP 3D Pro, by KaVo™, crystallizes the 50-year heritage of a legendary product family. It uses the latest in 3D and 2D technologies, for your benefit. The modern 3-in-1 platform’s flawless design and versatility set the benchmark for whole maxillofacial imaging.

  • 3-in-1 platform delivers high-quality images
  • Versatile selection of volumes and resolutions
  • Automatic dose control (ADC) technology with 3D
  • SMARTVIEW™ feature for accurate FOV positioning
  • Free FOV positioning in horizontal and vertical directions
  • Metal Artifact Reduction (MAR) tool
  • Large, easy-to-use 10-inch user interface enables efficient usage
  • Intuitive patient positioning
  • Designed to be upgradeable and expandable with a cephalometric option available

KaVo-OP-3D-Pro-cone-beam-details-gold-standard

Excellent Image Quality for Every Patient

Carefully planned features and FOV specifically optimized imaging parameters, together with the advanced ORTHOPANTOMOGRAPH technology, make OP 3D Pro the ideal tool for all dental imaging needs and the most comprehensive 3-in-1 platform for demanding professionals.

Versatile, optimized software enables efficient diagnosis, resulting in a fast and effortless workflow for all imaging modalities.

No compromises have been made in any of the many aspects of image quality. Both the volume and the resolution can be selected according to the indication and region of interest. Treatment plans can be made with confidence knowing that OP 3D Pro masters the details.


KaVo-OP-3D-Pro-cone-beam-details-positioning

​5 FOVs with Precise Positioning

Excellent imaging starts with accurate patient positioning. Patient positioning is intuitive and precise. Imaging modality and exposure values are smoothly set with the large 10" user interface.

With OP 3D Pro there is no need to compromise with FOV positioning. Horizontally, FOV can be positioned freely from the user interface. Vertically, free FOV positioning is achieved by motorized movements of the chinrest. For precise positioning that eliminates the risk of retake exposures, the OP 3D Pro can take a two-dimensional SMARTVIEW scout image before the CBCT examination. From the scout image the position of the volume can be verified or corrected if needed.


Upgradeable Platform

The OP 3D Pro units are designed as expandable platforms, with a cephalometric option available. Cephalometric can be left- or right-sided to ensure optimal system performance and ease of use and is field upgradeable. Unit handedness also can be changed in the field.


We Care for Your Patients’ Well-Being


 

OP 3D Pro — 5 available FOVs to choose from

FOV 5 x 5 cm


Optimized for single site implants or localized diagnostics, keeping the patient dose at a substantially reduced level.

KaVo-OP-3D-Pro-cone-beam-fov5x5

FOV 8 x 15 cm


Covers both mandibula and maxilla including airway and upper cervical spine or the sinus. Both TM joints also can be studied.

KaVo-OP-3D-Pro-cone-beam-fov8x15
 

FOV 6 x 8 cm


Covers the complete dental arch for multiple implant placement and allows for the use of surgical guides.

KaVo-OP-3D-Pro-cone-beam-fov6x8

FOV 13 x 15 cm


Covers the entire maxillofacial region. This FOV is optional.

KaVo-OP-3D-Pro-cone-beam-fov13x15

FOV 8 x 8 cm


Covers the entire dentition, including both mandibula and maxilla as well as a portion of maxillary sinus.

KaVo-OP-3D-Pro-cone-beam-fov
 

OP 3D Pro small panel — 2 available FOVs to choose from

FOV 6 x 4 cm


Optimized for single site implants or localized diagnostics, keeping the patient dose at a substantially reduced level.

KaVo-OP-3D-Pro-cone-beam-fov6x4

FOV 6 x 8 cm


Covers the complete dental arch for multiple implant placement and allows for the use of surgical guides.

KaVo-OP-3D-Pro-cone-beam-fov6x8

Automatic Dose Control (ADC)

With OP 3D Pro, proprietary ADC technology adaptively regulates panoramic exposure levels for each patient. It optimizes the dosage during every acquisition patient-specifically. ADC enhances the workflow efficiency because there is no need to select the exposure values manually.


KaVo-OP-3D-Pro-cone-beam-features-LDT

Resolution for Each Indication

  • Low Dose Technology (LDT) can be used in dose sensitive cases and control or follow-up situations where maximum resolution is not required.
  • Standard resolution scan takes only 10 seconds with exposure time only 2.3 seconds with optimized patient dose.
  • High resolution scan offers extremely sharp images for more detailed diagnosis.
  • Endo resolution scan is available with smallest FOV featuring 85 μm voxel size and MAR. Endo scan is tool designed for endodontic as well as other applications where extreme accuracy is required.

KaVo-OP-3D-Pro-cone-beam-features-MAR

Metal Artifact Reduction (MAR) tool

For implant or endodontic cases where metal artifacts are present, the metal artifact reduction tool (MAR) can be used for optimized images.


KaVo-OP-3D-Pro-cone-beam-features-smartview

SMARTVIEW™

A two-dimensional scout image can be taken before CBCT examination to adjust the target position visually from GUI screen. This guarantees precise positioning and eliminates risk of retake exposures.


KaVo-OP-3D-Pro-cone-beam-features-FOV

Free Field-of-view Positioning

With the OP 3D Pro, exposing a larger area than necessary in order to examine the area-of-interest is not a concern. The FOV location with all available FOVs can be positioned freely in both horizontal and vertical directions, with ease — offering the control needed to get the right image and assisting in limiting exposure to the patients.

 


Focal Spot

0.5 mm, IEC 336

Tube Voltage

57–90 kV

Tube Current

3.2–16 mA

Nominal Voltage

-

HU Capacity

35 kJ, 49 000 HU

Minimum Total Filtration

3.2 mm AI

Wheelchair accessible

Yes

2D Panoramic

Image Detector

CMOS

Sensor Pixel Size

100 µm

Image Pixel Size

100 µm

Scan/Exposure Time

8.6–16.1 seconds

Image Field Height

148 mm

Imaging Programs

Standard, Pediatric, Ortho Zone, Orthogonal, Wide Arch, Lateral TMJ, PA TMJ, Maxillary Sinus, Bitewing

Weight

200 kg / 440 lbs

2D Cephalometric

Image Detector

CMOS

Sensor Pixel Size

100 µm

Image Pixel Size

100 µm

Scan/Exposure Time

10–20 seconds

Image Field Height

17–260 mm

Weight

250 kg / 551 lbs

3D Small Panel

Image Detector

CMOS

Image Voxel Size

85–330 µm

Scan Time

11–21 seconds

Exposure Time

1.2–12.6 seconds

Image Volume Sizes (H x W)

61 x 41, 61 x 78 mm

DICOM Support

Yes

Min. room height

2050–2450 mm

3D Medium Panel

Image Detector

CMOS

Image Voxel Size

85–420 µm

Scan Time

11–42 seconds

Exposure Time

1.2–8.7 seconds

Image Volume Sizes (H x W)

50 x 50, 61 x 78, 78 x 78, 78 x1 50, 130 x 150 mm

DICOM Support

Yes

Min. room height

2050–2450 mm

Minimum System Requirements for 3D Acquisition Workstation

CPU (processor)

Intel® Core™ i5, i7 or Xeon®, 4‑cores or more

GPU (graphics processing unit)

NVIDIA® Quadro® M2000 4GB or GeForce® GTX 1050 Ti 4GB

RAM (memory)

8 GB or more

Storage (hard disk)

1 TB or more
RAID 1 or RAID 5 recommended for data
redundancy, plus backup

Network

Gigabit Ethernet 1000 Mb/s

Operating System

Windows® 10 Pro or Enterprise, 64‑bit
Windows 8.1 Pro or Enterprise, 64‑bit
Windows 7 Professional, Ultimate or
Enterprise, 64‑bit, with SP1

Display

1920 x 1080 resolution (Full HD) or higher, at least 300 cd/m2 brightness for typical room lighting, native contrast ratio 100:1 or better, 8‑bit panel strongly recommended

Other

OpenCL 1.1 support
DVD‑ROM drive
Anti‑virus software

Notes

Please refer to software and device installation manuals for detailed requirements

Core™, GeForce®, Intel®, Microsoft®, NVIDIA®, Quadro®, Windows® and Xeon® are trademarks of their respective owners.

 

Dimensional Drawings

KaVo-OP-3D-Pro-cone-beam-technical

Testimonials

What General Dentists Say About the OP 3D Pro

This 3D system makes me a better dental care provider. — Terry Work, DDS, General Dentist, Scottsdale, AZ Instrumentarium Dental owner since 2013* *Dr. Work is a paid consultant for KaVo. The opinions expressed here are those of Dr. Work.

Documentation

Document types

Language

Sort by

Elements per page

Displaying 1 - 1 of 1
KaVo OP3D Pro Brochure
Document Type: Product Brochure
Language: English (US)
Release date: 
Wednesday, 8 February, 2017 - 01:02
File size: 
3.20 mb