You can expect the following maintenance scope

1. Selective plunger
- Check function, clean, and replace O rings
- Disassemble and clean selective housing, replace strainers
- Disassemble selective plunger, replace springs (E70/E80) and seals
3. Suction flow valve / external suction
- Replace O ring and piston packing
5. Patient unit
- Tumbler spout: check operation and seal
- Replace jet control and O ring
- Bowl flush: check operation and seal
- Replace spittoon bowl strainer
Sequence
All maintenance steps follow KaVo's maintenance schedule and are documented step by step. You will receive a maintenance log as evidence.
2. Aquamat
- Check overall function
- Replace reservoir and clean top
4. Water unit
Check overall function / check for leakage
- Replace water filter, membrane, and seals
- Replace non-return valve
- Replace plug-in filter, water inlet unit fitting and O rings
- Check system water pressure and adjust if required
6. Dentist element
- Replace return air filter
- Disassemble and clean control valve
- Replace plunger, O-ring, and membrane
Planned maintenance intervals
All maintenance is performed according to KaVo’s maintenance schedule:
1. Checks
- As part of planned maintenance, all functions of the unit are checked.
- You will be provided with detailed information on all necessary maintenance tasks that are not included in the maintenance contract.
2. Replacements
- Regular exchange of wear parts in strict accordance with KaVo’s maintenance schedule.
- Settings of your treatment unit are modified or adjusted where required.
3. Certification
All legally required checks can be performed as part of annual planned maintenance:
- Safety checks in accordance with DIN EN 62353
- Checks of the integrated amalgam separator (in accordance with local regulations)
The service technician issues a maintenance log as evidence.
Benefit from our experience
- The scope of each one of KaVo's maintenance kits is based on many years of practical experience
- All maintenance kits are tailored to its respective treatment unit
- Wear parts are replaced in time and settings are corrected where required
- Have our certified specialist dealers do your maintenance
Requirements: Safety through maintenance
All legally required checks can be performed as part of annual planned maintenance:
- Safety checks
- Visual inspection
- Functional checks
- Electrical checks
- Check of amalgam separator (according to local regulations)
Maintenance and legally required checks are documented and serve as evidence in the surgery's certification or inspection by authorities.
Interested in maintenance service?
Request and make profit. Ordering is easy and takes only a few clicks. Your information will be passed from KaVo to your dental dealer and he will contact you immediately. KaVo recommend exclusiv cooperation with authorized dealers. Profit from regularly, professional and reliable maintenance service.